AMS-II.D requires that project equipment delivers measurable energy savings relative to the baseline.

check_applicability_energy_efficiency(
  baseline_data,
  project_data,
  fuel_col = "baseline_fuel_quantity",
  efficiency_col = "baseline_efficiency",
  project_fuel_col = "project_fuel_quantity",
  project_efficiency_col = "project_efficiency",
  tolerance = 0.1
)

Arguments

baseline_data

Tibble containing baseline fuel and efficiency metrics.

project_data

Tibble containing project fuel and efficiency metrics.

fuel_col

Baseline column storing fuel quantities.

efficiency_col

Baseline column storing equipment efficiency.

project_fuel_col

Project column storing fuel quantities.

project_efficiency_col

Project column storing equipment efficiency.

tolerance

Minimum fractional reduction in specific fuel consumption (fuel input per unit of baseline useful energy output) that must be achieved to satisfy the applicability condition.

Value

Logical scalar indicating whether the criterion is met.

Examples

baseline <- tibble::tibble(baseline_fuel_quantity = 1200, baseline_efficiency = 0.72)
project <- tibble::tibble(project_fuel_quantity = 950, project_efficiency = 0.84)
check_applicability_energy_efficiency(baseline, project)
#> Error: `service_col` must be present in both baseline and project data.